Our Products

The HE Series make-up air units offer the most efficient method available to heat make-up air. Direct fired make-up air heaters may be considered to be 100% efficient because no heat is vented to the atmosphere.

The theoretical 100% efficiency should be reduced to 92% due to water vapor being formed as a natural by-product of the combustion process. Units are available with heating capacities up to 14,000 MBH and air capacities up to 100,000 CFM. Units are also available in variable capacity, dual capacity, air curtain, and / or heat recovery configurations.

HE Series

Direct Fired Heaters

 

 

Features

  • 1,300 to 100,000 CFM
  • Up to 25:1 turndown
  • Indoor and outdoor configurations
  • High Efficiency Green Burn Burners
INTERTEK - C US - Listed
Green Burn Burners Learn More about GB

Typical Options ( * ) represents standards features

CASING

  • 18 gauge*
  • 14 or 16 gauge available
  • 1” or 2” insulation
  • Solid liners

FINISHES

  • Air dry gray enamel*
  • Corrosion protection
  • Special colours

ACCESS

  • Hinged doors*
  • Lined doors*
  • Camlock handles*
  • Leverlock handles
  • Service platform
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined

MOTORS

  • ODP*
  • TEFC
  • 2 speed
  • High efficiency

FILTERS

  • High velocity*
  • Replaceable media
  • 30% pleated panel
  • 1”, 2”, 4” or 12” as required
  • High effiency
  • Chemical filtration

GAS TRAIN

  • FM
  • IRI / CIRI
  • Up to 25:1 turndown

HEAT RECLAIM

  • QDT Heat Pipe
  • EngA Heat Wheel
  • Glycol Loop
  • Plate Type

COOLING

  • Packaged cooling
  • DX coil
  • Chilled water
  • Evaporative coolers

CONTROLS

  • Electronic
  • Maxitrol
  • M-TRAC

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The RE Series mix air units offer the most efficient method available to heat mix air. Direct fired make up air heaters may be considered to be 100% efficient because no heat is vented to the atmosphere.

The theoretical 100% efficiency should be reduced to 92% due to water vapor being formed as a natural by-product of the combustion process. Units are available with heating capacities up to 11,000 MBH and air capacities up to 100,000 CFM. Units are also available in variable capacity, dual capacity, air curtain, and/or heat recovery configurations.

RE Series

Direct Fired Heaters

 

 

Features

  • Variable Outdoor Air Volume
  • 1,600 to 100,000 CFM
  • Indoor / Outdoor / Horizontal / Vertical
  • High Efficiency Green Burn Burners
INTERTEK - C US - Listed
Green Burn Burners Learn More about GB

Typical Options ( * ) represents standards features

CASING

  • 18 gauge*
  • 14 or 16 gauge available
  • 1” or 2” insulation
  • Solid liners
  • Low leak dampers

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Corrosion protection

ACCESS

  • Hinged doors*
  • Lined doors*
  • Camlock handles*
  • Leverlock handles
  • Service platform
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined

MOTORS

  • ODP*
  • TEFC
  • 2 speed
  • High efficiency

FILTERS

  • High velocity*
  • Replaceable media
  • 30% pleated panel
  • 1”, 2”, 4” or 12” as required
  • High efficiency
  • Chemical filtration

GAS TRAIN

  • FM
  • IRI / CIRI
  • Up to 25:1 turndown

HEAT RECLAIM

  • QDT Heat Pipe
  • EngA Heat Wheel
  • Glycol Loop
  • Plate Type

COOLING

  • Packaged cooling
  • DX coil
  • Chilled water
  • Evaporative coolers

CONTROLS

  • Electronic
  • Maxitrol
  • M-TRAC

THIS CLASS OF PRODUCT NOT PRESENTLY APPROVED FOR USE IN CANADA
Application of this product requires written approval from the appropriate chief provincial gas inspector.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The DJ Series is divided into three models:

DJS Series

Our standard model DJS Series indirect fired heating operates with a nominal combustion efficiency of 81%.

DJE Series

The DJE Series indirect gas fired unit best matches our previous model series, also with the nominal combustion efficiency of 80%.

DJX Series

The most advanced model and highest combustion efficiency rating in the markeplace of 91% is the DJX Series indirect gas fired unit.

All DJ Series models feature high turndown burner, Stainless Steel two or three pass heat exchangers which offer longer heat exchanger life expectancy in cold climate operations with 100% outside air operation capability.

The DJ modes are available with heating capacities between 100 and 3,000 MBH. With the proven exclusive Engineered Air DJM Controller all DJ models are capable of 15:1 burner turn down ratios with a range of control options.

DJ Series

Commercial - Industrial Indirect Fired Heaters

 

 

Features


  • Airflow Rate from 1,000 to 44,000 CFM
  • Gas Input Capacities from 100 to 1,400 MBH
  • Turndown Ratio up to 15:1
  • Indoor and Outdoor Configurations
  • Vertical and Horizontal Arrangements
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge*
  • 1” insulation*
  • 2” insulation
  • 14 or 16 gauge available
  • Solid or perforated liners
  • Stainless Steel
  • Galvanized
  • Aluminum

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Corrosion protection - Heresite, Epoxy

ACCESS

  • Hinged doors*
  • Lined doors*
  • Camlock handles*
  • Leverlock handles
  • Lockable handles
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined
  • Propeller (air turnover)

MOTORS

  • High Efficiency ODP*
  • High Efficiency TEFC
  • Variable Speed Drives
  • Two Speed

FILTERS

  • MERV 8 Pleated*
  • Replaceable media
  • 1
  • HEPA
  • Chemical Filtration
  • TRIMED

GAS TRAIN

  • FM
  • GAP (formerly IRI)
  • Up to 15:1 turndown

HEAT RECLAIM

  • QDT Heat Pipe
  • Recovery Air Heat Wheel
  • TRP Air to Air Plate
  • Glycol Run Around

COOLING

  • Packaged DX Cooling
  • DX Coil
  • Chilled water coil
  • Evaporative coolers

CONTROLS

  • DJM modulating discharge air control
  • DJM modulating room control
  • BMS
  • Night Setback
  • Ambient reset
  • Room reset

Case Studies


  • Roxboro House - Calgary Sales Office - 42929 (C34647)

    After 28 years one of the original building corridor pressurization units required extensive repairs. Rather than fixing the original unit, the Condo Association started looking for new equipment that would improve operating efficiency and temperature control.
    Click to Learn More


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The DG Series indirect fired heating units utilize our Engineered Air High Turndown Burner or optional purchased burner. Our Stainless Steel two pass heat exchanger offers long life expectancy and efficiencies as high as 82%.

The DG Series of industrial indirect fired heaters offers heating capacities between 1,400 and 7,500 MBH. When supplied with the Engineered Air G-TRAC control and our High Turndown Burner, the unit is capable of 20:1 turn down ratios.

Optionally the DG Series units can be configured for high discharge temperature industrial applications.

DG Series

Commercial - Industrial Indirect Fired Heaters.

 

 

Features


  • 9,100 to 85,000 CFM
  • 1,500 MBH to 7,500 MBH input
  • Up to 20:1 Turndown
  • High efficiency heat exchangers
  • Indoor and outdoor configurations
  • Vertical or horizontal arrangements
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge painted galvanneal*
  • 14 or 16 gauge available
  • 1” insulation*
  • 2” insulation
  • Solid or perforated liners
  • Stainless Steel
  • Galvanized
  • Aluminum

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Corrosion Protection - HERESITE, Epoxy

ACCESS

  • Camlock handles*
  • Hinged doors*
  • Lined doors*
  • Leverlock handles
  • Lockable handles
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined
  • Propeller (air turnover)

MOTORS

  • High Efficiency ODP*
  • High Efficiency TEFC
  • Variable Speed Drives
  • Two speed

FILTERS

  • MERV 8 Pleated*
  • Replaceable media
  • 1”, 2”, 4” or 12” as required
  • HEPA
  • Chemical filtration
  • TRIMED

GAS TRAIN

  • FM
  • GAP (formerly IRI)
  • Up to 20:1 turndown

HEAT RECLAIM

  • QDT Heat Pipe
  • Recovery Air Heat Wheel
  • TRP Air to Air Plate
  • Glycol Run Around

COOLING

  • Packaged DX Cooling
  • DX coil
  • Chilled water coil
  • Evaporative coolers

CONTROLS

  • G-TRAC modulating discharge air control
  • G-TRAC modulating room control
  • BMS
  • Night setback
  • Ambient reset
  • Room reset
  • High / Low / Off

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Space Temp Air Turnover Systems offer a solution to the universal problems of heating high bay areas: stratification, uneven temperature, and high energy costs. Other heating systems, most notably unit heaters and infrared heaters, tend to intensify stratification, and provide “spot” heating. These systems cannot provide a uniform space temperature and increase the amount of energy required to heat the space. Learn More

DJP Series

Commercial - Industrial Air Turnover Systems

 

 

Features


  • Air capacity up to 150,000 CFM
  • Gas Fired Heating 100 MBH to 7,500 MBH input
  • Indoor / Outdoor Unit Configurations
  • Flexibility in MBH and CFM combinations
  • Optional Heating (Hydronic or Electric)
  • Optional Cooling (Chilled Water or DX)
  • Optional Outdoor Air Dampers
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge Satin Coat*
  • 14 or 16 gauge available
  • 1” or 2” insulation

FINISHES

  • Air dry enamel “Night Fighter Gray”*
  • Special Colours
  • Corrosion Protection

ACCESS

  • Lift out doors*
  • Hinged doors
  • Lined doors
  • Ventlock handles
  • Service platform

FANS

  • Propeller*
  • Forward curved
  • Air foil
  • Backward inclined

MOTORS

  • ODP*
  • TEFC
  • 2 speed
  • High efficiency

FILTERS

  • Replaceable media
  • Throw away
  • High velocity
  • 30% pleated

GAS TRAIN

  • FM
  • IRI / CIRI
  • High turndown

COOLING

  • Packaged Cooling
  • DX Coil
  • Chilled Water

CONTROLS

  • Hi / Lo / Off*
  • G-TRAC
  • DJM
  • C-TRAC
  • H-TRAC
  • METASYS

MISC

  • Hydronic Heat
  • Electric Heat
  • Mixing dampers
  • Outdoor Air damplers

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's LM / LMD Series custom air handling units offer you the best of all worlds in designing your air handling system. Combined with our custom coil manufacturing abilities the LM / LMD Series can be configured with heating coils, cooling coils, evaporative cooling sections, return air mixing box, or even heat recovery packages.

The LM series units are designed with forward curved fans, backward inclined fans, airfoil fans, or plenum fans.

LM / LMD Series

Commercial - Industrial Air Handlers

 

 

Features


  • Made to Order
  • Low, Medium and High Pressure Casing Construction
  • Indoor and Outdoor Construction
  • Multiple Arrangements
  • Factory Pre-Wired Control Options
  • Energy Recovery Options
  • Electric Heat
  • Food Grade HVAC Equipment
  • Wastewater Applications
INTERTEK - C US - Listed

Selection Flexibility


The custom design of the LM / LMD Series of air handling units allows component selections to suit the distinctive nature of each application. A variety of fans including forward curved, plenum, air foil and vane axial types are available to accomodate individual power, sound and economic criteria.

A wide choice of models is offered, including horizontal. vertical, draw-thru, blow-thru and multi-zone configurations for indoor and outdoor applications. Heating and cooling requirements can be met with optional hot water, steam, electric, chilled water and refrigerant coils.

A wide array of filtration, humidification and control options complement the line. Click for information about our EngArray


Quality and Reliability


Quality assurance and proven reliability are a result of well designed and rugged units built by experienced and qualified engineers, designers and assemblers.

Quality control inspections and rigorous testings are performed at all stages of manufacturing in Engineered Air's modern plants. LM / LMD units are certified by ETL.

High efficiency heating and cooling coils are produced by Engineered Air with hot water and chilled water coils being approved by AHRI.

LM / LMD units may be factory pre-wired with disconnect switches, motor starters, damper motors and controls, to reduce field installation costs and provide a fully tested and guaranteed product.


Custom Design


The standard LM / LMD Series of air handlers offers selection flexibility and versatility in design. In addition, CUSTOM DESIGNED units are available to accomodate special requirements, including large air flow capacities, physical limitations, hazardous locations, extreme climatic conditions and corrosive atmospheres.

Energy recovery LM / LMD units, incorporating enthalpy wheel, heat pipe, plate and coil runaround systems, provide substantial operating cost savings. An international network of Engineered Air sales offices with technical service support and dedicated personnel are equipped to provide prompt and efficient assistance.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's LMK Series custom air handling units offer you the best of all worlds in designing your air handling system. Our LMK electric heat units incorporate our H-TRAC binary control for heat modulation.

By staging the heat supplied this control minimizes utility bills while ensuring that the buildings comfort requirements are met. Our air handlers are catalogued with air capacities between 750 CFM and 70,000 CFM - (Custom applications provided up to 150,000 CFM).

LMK Series

Commercial - Industrial Electric Heaters

 

 

Features


INTERTEK - C US - Listed

Selection Flexibility


The custom design of the LMK series of air handling units allows component selections to suit the distinctive nature of each application. A variety of fans including forward curved, plenum, air foil and vane axial types are available to accomodate individual power, sound and economic criteria.

A wide choice of models is offered, including horizontal. vertical, draw-thru, blow-thru and multi-zone configurations for indoor and outdoor applications. Heating and cooling requirements can be met with optional hot water, steam, electric, chilled water and refrigerant coils.

A wide array of filtration, humidification and control options complement the line.


Quality and Reliability


Quality assurance and proven reliability are a result of well designed and rugged units built bu experienced and qualified engineers, designers and assemblers.

Quality control inspections and rigorous testings are performed at all stages of manufacturing in Engineered Air's modern plants. LMK units are certified by ETL.

High efficiency heating and cooling coils are produced by Engineered Air with hot water and chilled water coils being approved by AHRI.

LMK units may be factory pre-wired with disconnect switches, motor starters, damper motors and controls, to reduce field installation costs and provide a fully tested and guaranteed product.


Custom Design


The standard LMK Series of air handlers offers selection flexibility and versatility in design. In addition, CUSTOM DESIGNED units are available to accomodate special requirements, including large air flow capacities, physical limitations, hazardous locations, extreme climatic conditions and corrosive atmospheres.

Energy recovery LMK units, incorporating enthalpy wheel, heat pipe, plate and coil runaround systems, provide substantial operating cost savings. An international network of Engineered Air sales offices with technical service support and dedicated personnel are equipped to provide prompt and efficient assistance.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


A premium engineered equipment panel system. Specially designed for low temperature air handling units to prevent condensation from forming on the exterior panel and to reduce heat gain or loss. Features a concealed fastening system and a non-CFC polyurethane insulating core.

NTM Series

NTM Air Handling Units

 

 


Applications


Engineered Air’s NTM Series air handling unit panels are architecturally designed to complement the building envelope, while providing enhanced thermal insulation, particularly for outdoor units, but also for indoor applications where low temperature air is created within the air handler. The superior joint engineering assures an air tight, moisture resistant enclosure for air handlers and packaged HVAC equipment.

Construction


NTM Series panels are insulated with a non-CFC thermosetting polyurethane insulation that meets model building code specifications. Structural grade steel facings are precisely roll formed and foam insulation is expanded between the metal sheets in a state-of-the-art continuous production sequence that is fully computerized to ensure optimum quality and consistency in every panel.

Insulation


NTM "No-Through-Metal" Series panels with foamed polyurethane insulation is offered in 2” thickness. 4” thick panels are available at extra cost, an extended delivery.

Facings


NTM Series panels are faced with 26 gauge stucco embossed galvanized steel to ASTM-525 G-90 designation. Base steel shall be structural quality to minimum Grade A 33,000 psi, conforming to ASTM A-446. Optional panel facings of Galvalume, aluminum or stainless steel are available at extra cost and extended delivery.

Coating Systems


NTM Series panels are primed both sides with a 0.2 mil primer and finished on one or both sides as specified, with one of the following finishes:

  1. Electrostatically applied alkyd enamel: supplied in Night-Fighter Gray as standard, or colour to suit.
  2. Two part epoxy enamel with clear coat glossy finish. Approved for food contact areas in a limited range of colours.
Above finishes and colour options are at an extra cost.

Fire


Meets special requirements of model building codes and is certified and approved by the following authorities:

UL
Underwriters Laboratories Inc.
ULC
Underwriters Laboratories Canada
FM
Factory Mutual
WH
Warnock Hersey
NYFC
New York State Toxicity Standard
FM-4880
Class 1 Fire Rating
ASTM-E84
Flame Spread: 17 | Smoke Developed: 97
ULC-S102
Flame Spread: 22 | Smoke Developed: 67
UBC 17-6
Passed multi-storey test with standard panels

Thermal Properties Standard 2” panel


Transmission
0.061 BTU/hr × ft² × °F (including air films)
Resistance
15.6 °F × ft² × hr/BTU (panel only - no air films)

Vapor Barrier


ASTM E-238
Air Infiltration: 0.0015 CFM/ft² at 20 psf
ASTM E-331
Water Penetration: "0" at 20 psi

Structural


ASTM E-72
Vacuum chamber tested for wind and suction load deflections on wall assemblies
ASTM E-72-9
The panel achieved a vertical load bearing capacity on standard width to maximum 19,800 lbs. compressive force at 0.06” deflection
Fatigue Test
Standard panels were tested for long term deflection failure. The panels exceeded 2 million cycles without failure or deformation
Bond Strength
The panel was tested for Tensile Bond Strength of the metal-to-foam interface to more than 1200 lb. force without delamination.

Allowable Uniform Loads (PSF) for Maximum Deflection 1/180th of Span Length

Thickness Span (feet)
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
2” Std. 71.1 56.1 45.2 37.1 30.9 25.9 22.0 18.7 16.2 14.0 12.1 10.4
4” Opt. 121.9 98.8 82.2 69.6 59.8 51.9 45.4 40.0 35.5 31.6 28.2 25.2 22.5 19.8 17.9 15.9

Note: to determine static pressure within cabinet, multiply allowable loading in PSF by 0.192.
Example: 2’ panel with a 10 foot span can withstand an internal static pressure of 25.9 × 0.192 = 5.0”w.g.

If snow load or internal static pressure exceeds the unsupported span length,
an intermediate structural support will be provided to reduce excessive deflection.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Our FWE Series of packaged air conditioners are completely custom designed to meet your needs, the units can be configured in cooling only or heat cool design. We offer a large assortment of both new and retrofit multi-zone designs. This product can also be integrated with our heat wheel or heat pipe products to minimize equipment loads and facilitate dehumidification.

Standard configuration for an FWE series product includes forward curved fans but can be modified to include Backward Inclined fans, Airfoil fans, Plenum fans, etc...

FWE Series

Commercial & Industrial Mechanical Cooling / Heating Units

 

 

Features


  • Multiple staged compressors and / or modulating compressor
  • Energy efficiency verified models available
  • R-407C, R-410A and optional R-134a refrigerants
  • Direct or indirect gas-fired heaters (high efficiencies and turndowns)
  • Hydronic and electric heating coils
  • Total or sensible energy recovery components
  • Custom fans - EngArray
  • Your equipment solution for sustainable buildings
  • 6 through 120 tons of mechanical cooling
  • 1,600 to 56,000 CFM air volumes
  • Custom units for non-catalogued capacities
  • Multiple independent compressor circuits
  • Dedicated EngA TRAC Controllers
  • Unit base fabricated from steel channel
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge painted galvanneal*
  • 14 ga or 16 ga
  • 1” Insulation*
  • 2
  • Solid or perforated liners
  • Stainless steel
  • Galvanized
  • Aluminum

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Corrosion protection - HERESITE, Epoxy

ACCESS

  • Camlock handles*
  • Hinged doors*
  • Lined doors*
  • Leverlock handles
  • Lockable handles
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined
  • Plenum

MOTORS

  • High Efficiency ODP*
  • High Efficiency TEFC
  • Variable Speed Drives
  • Two speed

FILTERS

  • MERV 8 pleated*
  • Replaceable media
  • 1
  • HEPA
  • Chemical Filtration
  • TRIMED

GAS TRAIN

  • FM
  • GAP (formerly (IRI)
  • DG Series up to 20:1 turndown
  • DJ Series up to 15:1 turndown

HEAT RECLAIM

  • QDT heat pipe
  • Recovery Air Heat Wheel
  • TRP air to air plate
  • Glycol run around

COOLING

  • Packaged cooling with air cooled condenser*
  • R-410 or R-407C refrigerant*
  • R-134a refrigerant
  • Variable condenser reheat
  • Evaporative condensing section
  • Water cooled condenser

CONTROLS

  • C-TRAC
  • DJM
  • Networking capabilities
  • G-TRAC
  • H-TRAC
  • Night setback

Case Studies


  • Grant Bone and Joint Revitalization Project - Columbus, Ohio - D5582 (TC-597)

    The Grant Bone and Joint Center building was originally a downtown Holiday Inn that over the years had been modified. As a former hotel the facility did not have any existing mechanical rooms and space on the roof was already limited with the existing chillers and air handling equipment.
    Click to Learn More


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The UPEW Series of water-cooled packaged air conditioners provide a low cost, factory fabricated, cooling / air handling system requiring only a simple connection of the space thermostat and a supply of condenser water.

The UPEW Series lend themselves to small office buildings, commercial retail space and food service areas where the use of air-cooled equipment is not feasible. Water-cooled air conditioners provide significantly higher Energy Efficiency Ratios (EER).

Features


  • Pre-wired, water cooled packaged air conditioners
  • single & multiple quiet running gas cooled hermetic scroll type compressors
  • Resiliently mounted forward curved supply air blowers
  • Tube-in-tube refrigerant condensers
  • Sound treated compressor-condenser compartment
  • Two inch deep MERV 7 pleated filters
  • Vertical or horizontal (back or front) fan discharge
CSA - C US - Listed

Available Options


Air Handler
Airfoil fans (DIDW or SISW), plenum fans
Compressors
Hermetic reciprocating
Condensers
Cleanable shell and tube type, brazed plate stainless steel
Evaporators
Alternate tube circuiting
Filters
Cartridges, bags, HEPA and chemical types
Free Coolers
At lower outdoor temperatures, a separate hydronic coil to use with cooling towers
Glycol Condensing Circuits
Selections available
Heating Coils
Hydronic or electric
Variable Air Volume
Variable speed drives, inlet vanes
Silencers
Integral return air silencers, add-on supply air silencers
Sound Treated Casings
Extra heavy wall, 3-lb/ft3 rigid insulation, 24 ga. perforated liner

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air manufactures a variety of products that can be used for dehumidification.

Our PD Series of Pool Dehumidifier units cool, dehumidify and reheat air from pool areas. They can also incorporate heat recovery of the exhaust air for additional operating cost savings.

PD Series

Indoor / Outdoor Pool De-Humidifiers

 

 

Features


  • Indoor or outdoor models are available
  • Corrosion resistant Heresite coating is used on DX cooling and condenser coils
  • Compressor energy (heat) is reclaimed and used to heat pool water
  • Latent heat loss from the pool a water evaporates is reclaimed and rejected back into pool water and the pool supply
  • Auxiliary remote air cooled condensers are available which allows the system to provide space air conditioning
  • A variety of control options are available

Options


  • Return air fans and/or mixing boxes can be provided when required.
  • Auxiliary Engineered Air heating components (DJ, DG, electric, water, or steam coils) can be added to give a complete package.
  • Free cooling packages including motorized dampers (outside air, return air and exhaust air), as well as all economizer controls are available.
  • Whirlpool de-superheaters (selected for higher pool water temperature) are available.
  • Exhaust air heat reclaim systems using air to air, or heet pipe coils air available.

Benefits


Evaporating from the surface of an indoor swimming pool causes two major concerns. The first and most obvious problem relates to the resulting high relative humidity level.

During periods of low outside air temperatures, high indoor humidity causes problems with condensation and frost on windows.

A more serious problem could result if moisture penetrates into the building structure, where it could condense and freeze thereby causing structure damage.

The second major concern is heat loss from the surface of the swimming pool. As moisture evaporates from the surface of the pool, a large amount of heat is lost as the latent heat of evaporating is carried away by the moisture. If the humid air was simply exhausted, all of this latent heat would be lost and would have to be replaced by heating the pool water.

This discussion makes the benefits of an Engineered Air PD Series pool de-humidifier obvious. These benefits can be summarized as follows:

  1. Reduced pool heating costs due to reclamation of latent heat of evaporating from pool surface.
  2. Reduced space humidity levels prevents possible structural damage due to condensation.
  3. Space comfort conditions are also obviously improved by the lower relative humidity level. If a remote (outdoor) air-cooled condenser is used, the resulting space cooling ability also has obvious benefits.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air manufactures a variety of products that can be used for dehumidification. Our CD Series of Ice Rink Dehumidifier units solve the condensation problems frequently encountered in skating and curling rinks.

CD Series

Ice Rink De-Humidifiers

 

 


Application


A common problem encountered in skating or curling rinks is fog and / or moisture condensing and dripping from the structure. This occurs during periods when the space temperature is low and moisture content of the air relatively high. Condensation problems can occur throughout the year but more frequently occur during the spring and fall seasons.

In pool environments, outside air can often be used to condition the space and reduce the moisture level. This approach cannot be used in a rink environment because the outdoor air contains moisture with a higher dewpoint level than the indoor temperature of the rink. As a result, bringing in outdoor air for ventilation only adds to the fog and condensation problems.

The solution is to remove moisture from the ice rink air by using an Engineered Air dehumidifier. Our CD Series is one option. One alternative is the DWD Desiccant Gas Fired De-humidifier by Engineered Air.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The FW/HE series may be used to provide makeup air in commercial kitchens, cafeterias, and restaurants. In all cases, the exhaust air must be ± 10% of the makeup air, or as required by local codes.

FWE/HE units are available with side, up, or down discharge. Roof curbs are available where required.

FW / HE Unit

Direct Fired Makeup Air with Mechanical Cooling

 

 

Features

  • Energy efficiency verified models available
  • R-470C, R-410A and R-134a refrigerants
  • Multiple independent compressor circuits
  • Custom units for non-catalogued capacities
  • Dedicated Engineered Air TRAC controllers
  • EER ratings meet of exceed ASHRAE 90.1 requirements
  • High efficiency Green Burn burner
  • Packaged direct fired burner with mechanical cooling
INTERTEK - C US - Listed CSA - C US - Listed
Green Burn Burners Learn More about GB

Typical Options ( * ) represents standards features

CASING

  • 18 gauge*
  • 1” insulation*
  • 2” insulation
  • 14 or 16 gauge available
  • Solid or perforated liners

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Corrosion protection
  • Epoxy paint

ACCESS

  • Hinged doors*
  • Lined doors*
  • Camlock handles*
  • Levelock handles
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil *
  • Backward inclined

MOTORS

  • High E ODP*
  • Super E ODP
  • TEFC
  • Super E TEFC
  • 2 Speed

FILTERS

  • MERV 7 Pleated*
  • Cartridge
  • HEPA
  • Replaceable media
  • Custom filtration
  • Chemical filtration

GAS TRAIN

  • FM
  • GAP / IRI

HEAT RECLAIM

  • QDT heat pipe
  • Recovery Air Heat Wheel
  • Glycol Loop
  • TRP air to air plate

COOLING

  • Packaged cooling with air cooled condenser *
  • DX Coil *
  • Evaporative condensing section

CONTROLS

  • CTRAC control
  • MTRAC control
  • BacNet
  • Modbus

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


A makeup air unit combining the economy of efficient indirect fired heating with mechanical cooling. The option blow through filter and evaporator coil eliminates nuisance trip outs due to frosting during the winter months.

FW/DJ units are available with side, up or down discharge. Roof curbs are available where required.

FW / DJ Unit

Mechanical Cooling / Indirect Fired Makeup Air Unit

 

 

Features


  • Energy efficiency verified models available
  • R-407C, R-410A and R-134a refrigerants
  • Multiple independent compressor circuits
  • Custom units for non-catalogued capacities
  • Dedicated Engineered Air TRAC controllers
  • EER ratings meet or exceed ASHRAE 90.1 requirements
  • Indirect gas fired heat exchanger capable of 100% makeup air
  • Packaged indirect fired burner with mechanical cooling
INTERTEK - C US - Listed CSA - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge*
  • 1” insulation*
  • 2” insulation
  • 14 or 16 gauge available
  • solid or perforated liners

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Corrosion protection
  • Epoxy paint

ACCESS

  • Hinged doors*
  • Lined doors*
  • Camlock handles*
  • Leverlock handles
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined
  • Plenum

MOTORS

  • High E ODP*
  • Super E ODP
  • TEFC
  • Super E TEFC
  • 2 Speed

FILTERS

  • MERV 7 Pleated*
  • Cartridge
  • HEPA
  • Replaceable media
  • Custom filtration
  • Chemical filtration

GAS TRAIN

  • FM
  • GAP / IRI
  • DJ Series up to 15:1 turndown

HEAT RECLAIM

  • QDT heat pipe
  • Recovery Air Heat Wheel
  • Glycol Loop
  • TRP air to air plate

COOLING

  • Packaged cooling with air cooled condenser *
  • DX Coil *
  • Evaporative condensing section

CONTROLS

  • CTRAC Control
  • DJM Control
  • BacNet
  • Modbus

Applications


The FW/DJ Series is excellent in providing makeup air for hallway pressurization, industrial facilities, food processing, commercial kitchens, health care, laboratories, athletic facilities or anywhere there is a need to heat and cool 100% outdoor air.

Components


Burner / Blower
Refer to DJ Series Indirect Fired Heaters.
Compressor
Available in multiple hermetic scroll or reciprocating models that are similar to the FW Series cooling units.
Evaporator
Alternate tube coil that is individually selected to meet specific conditions of operation.
Controls
Refer to the Control Section or contact your Engineered Air Sales Representative

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


CU Series

Air Cooled Condensing Unit

 

 

Features


  • Multiple staged compressors and / or modulating compressor
  • Energy efficiency verified models available
  • R-407C, R-410A and optional R-134a refrigerants
  • Single circuited hermetic scroll compressors
  • Tandem circuited hermetic scroll compressors available
  • Your equipment solution for sustainable buildings
  • 3 to 120 ton units
  • Custom units for non-catalogued capacities
  • Multiple independent compressor circuits
  • Indoor and outdoor configurations
  • Unit base fabricated from steel channel
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 ga painted galvanneal*
  • Galvanized
  • Aluminum
  • Stainless steel
  • 14 ga or 16 ga

FINISHES

  • Air dry gray enamel*
  • Special colours
  • Special corrosion protection
  • Epoxy paint

FANS

  • Propeller*
  • Forward curved
  • Airfoil
  • Backward inclined

CONTROLS

  • Interstage & Anticycle timers*
  • C-TRAC control
  • Networking capabilities

COMPRESSORS

  • Single scroll*
  • Tandem scroll
  • Reciprocating

ADDITIONAL OPTIONS

  • Low ambient operation
  • Separate insulated compressor compartment
  • Pump down
  • Hot gas bypas
  • Suction line accumulator(s)
  • Receiver(s)
  • Shut off valves

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air has developed the FW/EC Series of packaged air conditioners to meet the demands for lower air supply temperatures, in the 44°F - 50°F range, while meeting the operating efficiencies of ASHRAE Standard 90.1.

The FW/EC series of air conditioners utilizes the benefits of evaporative cooling in the condenser, allowing condensing temperatures in the range of 100°F to 110°F, even with ambient dry bulb temperatures at 100°F or over, as long as the web bulb temperature of the outside air is at 80°F or lower.

Features


  • Meets or exceeds ASHRAE 90.1 efficiencies
  • Supply air temperatures as low as 44°F
  • Walk-in compressor section
  • Excellent serviceability
  • Full range of heating accessories
  • Full range of filtration accessories
  • Minimized unit footprint
INTERTEK - C US - Listed

Applications


Lower condensing temperatures with the resulting higher EER's mean lower operating costs for the owner. Even when operating cost is not a concern, (seldom the case), building code authorities may impose electrical energy input limits on the air conditioning system, most often along the lines laid out in the ASHRAE Standard 90.1.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Multizone Units for new or replacement applications designed to meet the needs of the 21st century.

Reduced energy consumption through:



  • up to 15:1 turndown with gas heat

  • multiple compressors

  • improved control systems

MZ Series

Commercial - Industrial Heating and Cooling

 

 

Features


  • Hot Deck available with Gas, Hydronic or Electric heat
  • Wide range of gas fired heating capacities
  • Available with DX or chilled water cooling
  • Multiple Compressors
  • Independently piped and circuited compressors
  • Hot gas bypass on lead compressor
  • 15:1 turndown on indirect gas fired hot deck
  • Hot deck temperature inversely reset from outdoor ambient
  • Z bar Roof Curb mating flanges
  • Interface with BMS (Build Management Systems) or existing 135 OHM room thermostats
  • Parallel flow hot / cold decks
  • Blow through cold deck
  • Hinged front access on unit discharge
  • Integrating increased cooling capacity on existing roof curbs
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge satin coat*
  • 14 or 16 gauge available
  • 1” or 2” insulation
  • Solid or perforated liners

FINISHES

  • Air dry enamel “Night Fighter Gray”*
  • Special Colours
  • Corrosion Protection

ACCESS

  • Hinged doors*
  • lined doors
  • Ventlock handles
  • Service platform
  • Service vestibule

FANS

  • Forward curved*
  • Airfoil
  • Backward inclined
  • Plenum

MOTORS

  • ODP*
  • TEFC
  • High Efficiency

FILTERS

  • 30% pleated*
  • Replaceable media
  • 1”, 2”, 4” or 12” as required
  • High efficiency
  • Carbon filtration

GAS TRAIN

  • FM
  • IRI / CIRI
  • Up to 15:1 turndown

HEAT RECLAIM

  • QDT Heat Pipe
  • EngA Heat Wheel
  • Glycol Loop
  • Plate Type

COOLING

  • Packaged Cooling
  • DX Coil
  • Chilled Water
  • Evaporative Coolers

CONTROLS

  • C-TRAC control of cold deck
  • DJM control of hot deck
  • METASYS
  • Night Setback

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air is the proven leader in combustion and heat exchanger technologies. Our high turndown burner and floating, stress relieved heat exchanger have been quality tested for over 25 years of use involving thousands of installations.

Dedicated Engineered Air controls, specifically designed for EngA Burners, are used to achieve up to 15:1 fully modulating turndown ratio. The ability to modulate the combustion process, while maintaining or increasing the efficiency throughout the turn down range, results in the lowest energy cost per pound of steam produced.

This recognized combination of Engineered Air TRAC controller, burner and heat exchanger is further enhanced to achieve minimum capacity duration at high altitudes.

These proven technologies are the heart of the Engineered Air SH Gas Fired Humidifier. Learn More

SH Series

Commercial - Industrial Gas Fired Steam Humidifier

 

 

Features


  • Up to 650 pounds of steam per hour
  • Engineered Air Combustion Technology
  • Up to 15:1 fully modulating turndown ratio
  • High efficiency heat exchangers
  • Low profile arrangement
  • Large tank for less interruption
INTERTEK - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 18 gauge Satin Coat*
  • 1” insulation*
  • 16 gauge optional
  • 14 gauge optional

FINISHES

  • Air dry gray enamel*
  • Custom Colours
  • Additional corrosion protection

ACCESS

  • Hinged Doors*
  • Lift Out Doors
  • Lever-lock handles

GAS TRAIN

  • S-TRAC control*
  • FM
  • IRI / CIRI

TANK/HTX

  • 18 gauge 316L SS (SH-240 & smaller)*
  • 16 gauge 316L SS (SH-400, 650)*
  • 14 gauge 316L SS

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's HE / DWD Series of fully packaged process / industrial units are ideal for removing moisture in a variety of applications, even in low humidity conditions.

Features


  • Indoor and outdoor models are available.
  • 1500 to 15000 CFM process air.
  • Lightweight, thermally and chemically stable, high performance and low maintenance desiccant wheels using activated silica gel for effective moisture and adsorption even in low humidity conditions.
  • Sizes available to dehumidify the process air below 40°F dewpoint and remove up to 470 lb/hr moisture @ 60°F DB / 90%RH.
  • High efficiency Engineered Air 20:1 high turndown Green Burn direct-fired burner used for desiccant wheel regeneration.
  • EngA air mixer enhances moisture removal by providing thorough air coverage onto the face of the desiccant wheel.
INTERTEK - C US - Listed

Applications


  • Ice rink
  • Critical temperature storage such as library archive storage
  • Production lines for pharmaceuticals
  • Production lines for plastic products
  • Dehumidification at fertilizer plants
  • Food drying
  • Museum
  • Environmental test room
  • Powder filling applications

Fundamentals of Operation


  • The Engineered Air HE/DWD Series gas fired desiccant dehumidifier uses vapor pressure differential to absorb moisture on the relatively cool process air side and then drive this moisture off in the hot regeneration airstream. The process air is hence dehumidified.
  • The desiccant wheel rotates constantly through the process air and the regeneration airstreams.
  • The ambient regeneration air is heated by an Engineered Air direct fired burner (HE Series). The water molecules transferred from the process air are then discharged to the ambient.

Benefits


  • Gas fired dehumidification units do not have a DX coil and inherent freezing problems associated with a low temperature DX coil. With mechanical cooling dehumidification, the condensed moisture will freeze on the surface of the evaporating coil when the coil surface is below 32°F as is sometimes necessary to reach low dewpoint levels. As a result, the minimum achievable dewpoint is limited by frosting on the DX coil.
  • Lower operating cost — especially in areas where the electricity cost is high and the natural gas cost is low. Mechanical cooling compressors require a significant amount of electricity to provide dehumidification.
  • No water condensation issues — the mechanical cooling dehumidification evaporator will condense water which will promote undesired microbial growth in the system/
  • Lower maintenance cost — gas fired desiccant dehumidifier has fewer components to service than mechanical cooling dehumidification units.

Options


  • Mixing boxes can be provided if required.
  • Auxiliary Engineered Air cooling components (FW mechanical cooling or chilled water coil) can be added to re-cool dehumidified process air to neutral condition.
  • A sensible heat wheel can be added to re-cool the process air down stream of desiccant wheel and preheat the regeneration air upstream of Engineered Air's burner.
  • High temperature process exhaust heat (approximately 125°F to 280°F) from the building, steam or electric heat, if available, can be used in the regeneration air to reduce the required heating capacity or eliminate the direct fired burner.
  • A cooling coil (DX or chilled water) could be used as an option to re-cool the warm dehumidified air.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's HRP Series is an energy recovery package specifically designed to reduce the high cost of conditioning ventilation air by recovering a significant portion of the thermal energy from the exhaust air. This is accomplished with EngA's QDT Heat Pipe which has a nominal 60% recovery factor. Learn More

HRP Series

Industrial Air to Air Thermal Recovery Units with QDT Heat Pipe

 

 

Features


  • Energy Savings
  • Choice of Blower Types
  • Gas, Electric, Hot Water or Glycol Heating
  • Chilled Water or DX Cooling Coil
  • Indoor and Outdoor
  • Filter Options
  • Computerized Heat Pipe Sizing

QDT

The Practical Heat Exchanger for Industrial Heat Recovery


Although industrial process exhaust contains valuable thermal energy, it generally contains contaminants in the form of condensables, corrosives or particulates. These complicate energy recovery efforts.

An effective heat exchanger must be able to separate the BTUs from the dirty air. This requires both a versatile heat exchanger design plus the engineering know-how and experience to properly apply it. Engineered Air, with its HRP Series of Packaged Heat Recovery units, offers you both.

The HRP Series is an air-to-air heat pipe heat exchanger specifically designed for the complexities of industrial heat recovery.

It has the following advantages:

No moving parts
Nothing to wear out, so the HRP Series has an extremely long lifetime with no mechanical maintenance.
No cross
contamination
Sealed partition separates the two airflows preventing contamination of the fresh air by the exhaust.
Self-contained
Requires no external power of operation.
Minimum cleaning
Specially designed with fewer fins on the dirty process exhaust side than on the clean fresh air side. Industrial HRP Series have flat, continuous plate fins to provide see-thru, clean-thru™ capability. Built-up dirt can easily be flushed during cleaning.
Size flexibility
A wide range of sizes are available that can be installed singly or as modules to meet the requirements of almost any airflow system.
Performance
flexibility
A wide range in the number of rows of heat pipes are available to provide desired recovery performance while still affording minimum cleaning maintenance. Buy only the amount of recovery you need.
Material flexibility
Available in different materials of construction to accommodate various corrosive effluents. Heresite® protective coating is also available for temperatures up to 400°F
Compact
HRP Series range from 6 to 16 inches deep in the direction of flow which reduces space required, lowers installation costs, provides ease of handling and simplifies cleaning.
Structurally sound
Constructed of heavy gauge materials to easily withstand the rigors of industrial environments.

In short, the Industrial HRP Series has the versatility needed to meet the varied conditions of industrial heat recovery. In addition, Engineered Air has the knowledge and experience to successfully apply this versatility to solve your heat recovery problems.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Our custom manufacturing facilities allow us to incorporate HRW Heat Wheels into products such as Indirect-Fired Gas Heating and Mechanical Cooling equipment.

When providing 100% outside ventilation air the Total Energy Wheel can drastically reduce cooling loads, heating loads and help to control humidity problems in any building. Combined with our state of the art W-TRAC controller we help you maximize building efficiency in both summer and winter applications. Learn More

HRW Series

Packaged Heat Recovery with EngA's Total Energy Wheel

 

 

Features


  • Energy Savings
  • Choice of Blower Types
  • Indoor and Outdoor
  • Chilled Water or DX Cooling
  • Gas, Electric or Hot Water Heating
  • Filter Options
  • Computerized Wheel Sizing

Recovery Air

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's HRA Series is an energy recovery package specifically designed to reduce the high costs of conditioning ventilation air by recovering a significant portion of the thermal energy from the exhaust air.

Application


Air to air heat exchangers can be employed in any ventilation system to reduce energy consumption. Systems that see the greatest benefit are the ones that have high volumes of hot exhaust air that also need to preheat cold outside air.

With options including auxiliary heating, cooling, flexibility in unit configurations, control systems and protective coatings, HRA units can be effectively used in many situations. Learn More

HRA Series

Packaged Heat Recovery with EngA's TRP Air to Air Heat Exchanger

 

 

Features


  • Energy Savings
  • Gas, Electric, Hot Water, Steam or Glycol Heating
  • Chilled Water or DX Cooling Coil
  • Choice of Blower Types
  • Indoor or Outdoor
  • Filter Options
  • Computerized Heat Exchanger Sizing

TRP

Benefits of Heat Recovery


  • Heat recovery from exhaust air can significantly reduce the ever increasing operating costs of heating, air conditioning and ventilating
  • The initial investment made into the heat recovery equipment is easily recovered because of lower operating costs
  • Less environmental pollution due to lower energy consumption
  • Added benefit of "air to air" plate type heat exchangers are:
    • Virtually complete separation of the air streams
    • No moving parts
    • No wear, thus low maintenance costs
    • Long life
    • Not susceptible to breakdowns

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


A completely packaged system of HEAT RECLAIM including supply and exhaust blowers, heat transfer coils, filtration, supplemental heating, temperature controls and limits, and roof mounting frames.

Combined with proven Engineered Air heating systems to augment the reclaim system:

HE Series
Direct Fired Burners

HE-K Series
Electric Resistance Heaters

DG Series
Industrial Gas or Oil Burners

LM Series
Hydronic Heating


Utilize the Engineered Air computerized coil selection process to optimize the fluid handling system components for maximum efficiency and minimum cost.

HRG Series

Glycol Run Around Heat Reclaim System

 

 

Optional Features


  • Piping enclosures, insulated and weather proofed for outdoor installations
  • Pipe insulation
  • Exhaust coil wash-down plenum and drain pan
  • Steel tube, aluminum fin coil
  • Special dimensions and configurations

Where should HRG Series be used?


  1. Commercial and industrial buildings, where exhaust and makeup are required for many hours of the year, the more hours the better.
  2. In installations where exhaust air temperatures are from 80°F to 200°F and where the air is not particularly corrosive. Exhaust air temperatures below 80°F tend not to be an economic source of heat, particularly where outdoor air temperatures are sub zero, and the possibility of circulating glycol at temperatures below 32°F exists, thus creating certain frosting conditions on the exhaust coil, which is a dehumidifying coil. While the control system can automatically prevent frost from forming, the efficiency of the system is low while operating in a "frost prevention" mode and energy savings may be less than anticipated.
  3. Areas of the country where the normal energy source is relatively expensive will be attractive for heat reclaim systems: the relative cost of energy seems to be rising at an alarming rate throughout all of Canada, so few areas will not find the reclaim of heat a wise economic move.

Why a HRG Series System instead of an Air to Air System?


The reclaim of heat, as developed so far, while saving heating energy, does demand the expenditure of energy in another form; fan motor horsepower to overcome the reclaim device air pressure drop. A glycol run around system requires about the same amount of extra energy to run the two fans and one pump, than an air to air system does for its two fans. However, in the glycol system, the pump may be shut off at a point when it is determined that heating savings no longer outweigh the cost for pump power.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's UV-C Lighting System, UV-Centurion, uses the latest UV-C lighting technology to control surface mold and microbial growth on your Air Handling Unit's (AHU) cooling coil, drain pan and filter bank. Placement of the UV-Centurion within the AHU is critical to properly irradiate the surface pathogens. Use of this total lighting system ensures the absence of surface growth, providing reduced maintenance costs and continued maximum operational efficiency of the air handling unit.

UV-Centurion direct and indirect irradiation design provides proper UV-C ray dispersion to cover the total controlled surface, killing most common molds, bacteria and viruses in under 60 seconds.

UV-Centurion triple zone coverage separates the rain pan/lower cooling coil module from the cooling coil / filter module to irradiate the areas where molds, viruses and bacteria are most likely to collect. This combination creates system lethal to pathogens. The drain pan module with reflector , directly and indirectly cover Engineered Air's Fast Pan / drain pan system keeping them clean and free flowing. The coil face / filter module continually bathe the face of the cooling coil killing any pathogens that may be deposited there, keeping them from multiplying and eventually clogging the coil. The downstream side of the filters is also bathed continually in UV-C, killing any growth on the leaving side before it can be released downstream.

Features & Benefits

High Output Lamps
Quicker killing of molds, bacteria and viruses

Total Control System
Provides triple zone coverage

High Polish Reflector
Maximizes UV-C intensity and dispersion

Pathogen Free Environment
Reduces maintenance costs, improves running efficiencies and IAQ

Keyed Lamp/Ballast Connector
Ensures proper tower to each UV-C lamp

Modular Design
Can be installed in existing systems

Sleeved Drain Pan Modules
Impervious to water, controlled operating temperatures.

Chemical Free
No harmful effects from hazardous chemicals

9000 Hours Life
Continuous cleansing of all services

UVC Series

EngA's UV Centurion Lighting System

 

 

Common Micro Organisms Affected by Germicidial Light

NAME LETHAL DOSE (µW-sec/cm&sep2;)
Bacillus Anthracis 4,520
Corynebacterium Diptheriae 3,370
Escherichia Coli (e coli) 3,000
B. Subtilis 7,100
Micrococcus Candidas 6,050
Mycobacterium Tuberculosis 10,000
Dysentery Bacilli 2,200
Spirillum Rubrum 4,400
Streptococcus Lactis 6,150
Penicillium Expansum 13,000

Features


  • Control of virus, bacteria, mold and algae
  • Triple zone system
  • Easily serviced
  • Safety Interlock
  • High output lamp technology
INTERTEK - C US - Listed

Case Studies


  • Grant Bone and Joint Revitalization Project - Columbus, Ohio - D5582 (TC-597)

    The Grant Bone and Joint Center building was originally a downtown Holiday Inn that over the years had been modified. As a former hotel the facility did not have any existing mechanical rooms and space on the roof was already limited with the existing chillers and air handling equipment.
    Click to Learn More


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The SI Series Oxidizer Units are self-contained air purification products designed to reduce high concentrations of odor & VOCs. They are a very economical solution, using minimal power consumption & requiring no additional chemicals or high priced media for operation and have extremely low maintenance.

The Oxidizer process is simple. High static voltage ionizes oxygen and then using basic principles of organic chemistry it naturally breaks down (oxidizes) gaseous compounds, leaving CO2, H2O and O2 as the primary end products.

For maximum results, the Oxidizer units should be connected to the suction side of any ducted system to maximize contact time between the oxidant and odorous gases.

The Oxidizer units are easily adaptable to the A-TAC1 system to create an automated air purification system, continually balancing oxidant levels with load levels for the air.

The Oxidizer will treat air problems in spaces where there are no existing air ducts2 or can be used to inject ozone into ducted air systems.

1 A-TAC is a series of IAQ sensors for air sampling on equipment regulation
2 recommended use with A-TAC system if used in occupied space.

larger models are available
contact factory
for sizing assistance

Oxidizer Model Selection Chart

Oxidizer
Model
Coverage Range of
AHU by CFM
Oxidizer
Blower Size
Mounting
Weight
Adaptable
to A-TAC
Discharge
Opening
Fan
Control
SI-200 500 - 5,000 140 CFM 25 lbs yes 3” 0 - 100%
SI-500 1,500 - 10,000 140 CFM 27 lbs yes 3” 0 - 100%
SI-1000 3,500 - 25,000 180 CFM 35 lbs yes 3” 0 - 100%

Features


  • Forward curved blower delivers maximum air flow with high static capability
  • High efficiency double screen discharge plates
  • Large air inlet with 2 ply poly pad filters for maximum plate protection against particulates, extending cleaning intervals
  • Variable speed fan / multi-speed fan control with hour meter
  • Heavy gauge steel construction
  • High output at high air volumes for maximum grams/hr rating (gm/hr)
  • Easily adapted to A-TAC automatic monitoring and control system
  • Safety Interlock Switch for safety during maintenance
  • Large air discharge outlet for maximum grams of deliverable oxidant
  • Remote mounting capabilities allows charged oxygen to be ducted into areas where there are heavy particulate loads, high humidity or other challenges while keeping the Oxidizer in a safe environment

Odorous Gases that can be Neutralized


  • Formaldehyde, Xylene, Toluene, Styrene
  • Glutaraldehyde, Carbon Monoxide, Acetone,
  • Benzene, Hydrogen Sulfide, Ammonia, Ketone
  • Complex ETS (tobacco smoke) gases and general food odors

Recommended Applications


  • Paint booths, large trash bins, building exhaust systems
  • Printing shops, manufacturing areas, food storage containers
  • Casinos, bars, restaurants, bowling alleys, wastewater facilities
  • Morgues, animal containment buildings

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Oxidation Process


Oxidation technology can be effectively employed to break down odorous gases formed in wastewater facilities or any industrial site that causes problems for those living or working nearby. The oxidation process allows a form of oxygen (ozone) to combine with odorous molecules to break down the chemical structure and reform the atoms into simple compounds. Ozone is found naturally in the outdoors. Ozone is created by ultra violet rays from the sun or by high voltage electrical discharge during lightning storms. EngA’s Oxidizer 2000 copies nature by using high voltage to create a concentrated ozone discharge.

The TRI MED® Patented Process


The Oxidizer 2000 produces concentrated ozone within high voltage modules. A powerful fan draws the ozone from the modules combining them with the odorous gas molecules. The mixture of ozone and odorous gases is discharged into a specially designed reaction chamber. Chemical reactions take place that result in a deodorized mixture that is discharged to atmosphere. This patented process is completed with minimal operating cost, no hazardous waste to dispose of and no costly consumables to replace.

Oxidizer Features


  • Corrosion resistant stainless steel enclosure
  • High voltage / high output modules with removable and cleanable components
  • High efficiency outside air filters
  • Hinged doors for easy access to internal components
  • Variable oxidation output allows easy adjustment to match applications
  • Extended duct collars for easy installation
  • Epoxy coated direct drive fan available in two sizes
  • Motor mounted in ventilated cabinet out of air stream
  • Adjustable speed controls
  • 120/1/60 supply power non-fused disconnect switch
  • Main control panel with NEMA 12 rated lights and switches
  • Hour meter for maintenance schedule tracking
  • 12 month warranty
INTERTEK - C US - Listed

Reaction Chamber Features


  • All stainless steel construction with condensate drain
  • Multi-Channel, low static, hight retention time design
  • Requires no chemical additives or internal replacement media
  • Extended duct collars for easy installation
  • 12-month warranty

Applications


  • Lift Stations, Manholes, Syphones
  • Grit Rooms, Head Works, Belt Press
  • Process Areas, Sludge Tanks

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air offers an extensive line of hot water, chilled water and steam heating products for commercial, industrial and institutional application. As with all Engineered Air products our Heat Transfer Products can be customized to meet your specific needs.

Engineered Air offers either copper or steel tube element to meet you finned tube radiation requirements. Our Galvanneal steel enclosure is treated with a multi-step Oakite Cryscoat preparation before being electrostatically painted with an epoxy powder coat prime finish. You then can choose from a variety of colours at minimal additional cost for your custom baked enamel finish coat. We offer a wide variety of enclosure styles as well as custom designed enclosure.

WF Series

Finned Tubed Radiation

 

 


Enclosures


Engineered Air standard enclosures are produced in the following styles: Slope Top (WF-1), Flat Top (WF-2) and Front Outlet (WF-3). Enclosure inlets can be supplied with Open Bottom (Type A), Slope Bottom (Type B) and Front Inlet Grille (Type C). Models are available in a variety of heights from 6” (152mm) to 36” (914mm) with lengths from 2’-0” (610mm) to 6 ’-0” (1829mm) increments.

In addition to standard enclosures, Engineered Air can provide, upon request, custom designed models in a size, metal type, gauge and paint finish to suit any desired application.

Accessories


For ease of installation and design continuity, Engineered Air manufactures brackets, element hangers, joggle strips, end caps, inside and outside corners, laps, access doors, pilaster kits and manual dampers, manual dampers must be factory installed.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Profile Series

Finned Tubed Radiation

 

 


Enclosures


The Engineered Air Profiles Series enclosure is produced in heights of either 8” (203mm) or 10” (254mm). The Profile Series enclosure is available in lengths from 2’-0” (610mm) to 7’ - 6” (2286mm) in 6” (152mm) increments.

In addition to Profile Series enclosures, Engineered Air can provide, upon request, custom designed models in a size, metal type, gauge and paint finish to suit any desired application.

Accessories


For ease of installation and design continuity, Engineered Air manufactures brackets, element hangers, joggle strips, end caps, inside and outside corners, laps, access doors, pilaster kits and manual dampers, manual dampers must be factory installed.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


C Series

Convector Radiators

 

 


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


CUH Series

Cabinet Unit Heaters

 

 

CSA - C US - Listed

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air manufactures the complete line of Horizontal and Vertical Unit Heaters with the following options: minimum 18 gauge (1.3mm) 304 Stainless Steel with Heresite coated coils and Totally Enclosed motors. The Stainless Steel Unit Heater is more than just great looks!


Forestry
Pulp & Paper
Petrochemical
The Stainless Steel Horizontal and Vertical Unit Heaters meet a demand in the industry for corrosion resistant products.

Pharmaceutical
Built to meet the cleanliness requirements of this industry.

Wash Facilities
Wash areas are one of the most corrosive environments, but are often forgotten when it comes to material selection.

Livestock / Zoos
Research
Surprisingly corrosive! Another great application for s Stainless Steel Unit Heater.

H Series

Horizontal Unit Heaters

 

 

Options


  • Stainless Steel Casing
  • Heresite Coated Coil
  • Totally Enclosed Motor
CSA - C US - Listed

Benefits


  • Extended Life
  • Corrosion Resistant
  • Additional Protection

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air manufactures the complete line of Horizontal and Vertical Unit Heaters with the following options: minimum 18 gauge (1.3mm) 304 Stainless Steel with Heresite coated coils and Totally Enclosed motors. The Stainless Steel Unit Heater is more than just great looks!


Forestry
Pulp & Paper
Petrochemical
The Stainless Steel Horizontal and Vertical Unit Heaters meet a demand in the industry for corrosion resistant products.

Pharmaceutical
Built to meet the cleanliness requirements of this industry.

Wash Facilities
Wash areas are one of the most corrosive environments, but are often forgotten when it comes to material selection.

Livestock / Zoos
Research
Surprisingly corrosive! Another great application for s Stainless Steel Unit Heater.

V Series

Vertical Unit Heaters

 

 

Options


  • Stainless Steel Casing
  • Heresite Coated Coil
  • Totally Enclosed Motor
CSA - C US - Listed

Benefits


  • Extended Life
  • Corrosion Resistant
  • Additional Protection

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air EngFlo forced convection finned tube radiation features high capacity in a small profile. Quality aluminum tangential blowers provide forced convection for those high heat loss areas.

Engineered Air's rugged 16 gauge (1.5mm) construction is standard in our two units, EF-50, 50" (1270mm) and EF-100, 100" (2540mm). The EF-100 consists of (2) 50" (1270mm) covers and (1) 100" (2540mm) base unit.

Engineered Air EngFlo units can be mounted in a variety of different arrangements; wall mounted, floor mounted, ceiling hung, free standing and recessed in wall or floor. Custom configurations and materials are also available.

EngFlo Series

Forced Convection Radiators

 

 

CSA - C US - Listed

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air high performance heat transfer coils have found wide acceptance in heating, cooling, dehumidification and heat reclaim applications, ranging from schools, churches, hospitals and high rise buildings to gas plants and manufacturing facilities. Engineered Air heat reclaim coils utilizing glycol or refrigerant provide substantial savings each year to owners of computer rooms, supermarkets, industrial process plants and other applications.

Steam coils are available in standard and "steam distributing" configuration, in both 5/8" and 1" diameter tubes.

Engineered Air is proud to be able to provide replacement coils duplicating virtually any type of coil, regardless of make, age, materials, construction or dimensions. Performance is guaranteed and deliveries are fast.

Heat Transfer Coils

Wide Variety of Coils

 

 

Features


  • Hot Water, Glycol, Steam Heating
  • Chilled Water, Glycol, DX Cooling
  • Variety of Materials and Applications
  • CSA B51 Registration

Computer-aided Design


Engineered Air has developed computer programs for the selection of hot water, chilled water, steam, refrigerant and heat reclaim coils.

These advanced programs can quickly and accurately optimized coils selections by providing a choice of several coils to satisfy load requirements and system design parameters.

The broad flexibility inherent in the computer programs allows selection decisions based on initial versus operating costs.

Customer assistance is provided by a staff of trained sales people located in Engineered Air offices across Canada and the United States.

Quality Assurance


Pressure testing tanks are but one of the various inspection stages each coil undergoes prior to shipment. Visual and dimensional checks are performed during and dimensional checks are performed during assembly and upon completion to verify manufacturing accuracy.

All coils are visually checked before being subjected to a final pressure test at 300psi under water, to insure compliance with required working pressures. All resale coils bear CSA certification for Canada and the USA and catalog data provides ARI certified ratings for 5/8 water coils. Engineered Air is registered to meet the requirements of the CSA B51 Pressure Vessel Code.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Unit Ventilators are made by the Heat Transfer Division of Engineered Air in four basic models, all in either draw through or blow through coil configurations. The 4 models are traditional vertical, horizontal ceiling, single fan horizontal ceiling and floor to ceiling riser style. All models are available with self-contained DX cooling and/or Heat Recovery options.

A Unit Ventilator for Every Application


HUV Series
Horizontal Multi-fan

RUV Series
Riser Style

SUV Series
Horizontal Single Fan

VUV Series
Vertical Floor Mounted


The VUV Series unit ventilator with its traditional arrangement is well known. Engineered Air brings a breath of fresh air to older buildings with our custom, built to fit replacement units. All models are capable of 0 to 100% outside air. The VUV is typically floor mounted on an exterior wall where fresh air is readily accessible.

The SUV Series single fan ceiling mounted unit ventilator may be just what you need. The linear arrangement could solve that tight ceiling problem. The 14 gauge fan board and full 1’ acoustic insulation, standard on all Engineered Air unit ventilators, insures quiet operation. Recessed installations have bottom access with optional hinged doors. For fully concealed SUV units, side access is recommended.

The small footprint of the RUV Series means more usable floor area. With vertical up and down flow, blow through and draw through models, Engineered Air has an arrangement for every situation. The RUV base height is adjusted to suit any floor to ceiling dimension. All Engineered Air unit ventilators features sloped stainless steel drain pans for positive condensate removal and long life. Lateral discharge ducts of rugged 16 gauge steel can be provided for down flow units. Lateral ducts have integral pencil proof louvres and are available in matching colours.

The HUV Series unit ventilator for concealed or exposed ceiling installations rounds out our family of unit ventilators. The HUV can be installed exposed (below the ceiling), flush mounted or concealed. All of our unit ventilators can be supplied with your choice of steam, water or electric heating coils and DX or water cooling coils. Duct discharge or integral grilles are available.

Engineered Air can also provide any of the models with self-contained DX cooling. This eliminates the need for outdoor condensing units that are subject to vandalism and damage. Using quiet and efficient scroll compressors provides cooling in areas that are occupied year round and allows the central plant to be shut down during idle times.

UV Series

 

 

Features


  • 4 models to choose from
  • Units from 600 to 2400 CFM
  • Self-contained DX units available
  • Custom built to specific dimensions
  • Standard 16 gauge construction (14 gauge optional)
  • Electrostatically applied baked polyester powder coat textured paint
  • Multiple access panels
  • Large piping pockets
  • Allen key camlock fasteners
  • Standard 14 gauge fan boards and all steel housing with galvanized steel blowers
  • Optional slide out fan boards
  • 1 inch 3 pound per cubic foot insulation
  • Engineered Air manufactured high capacity coils
  • Stainless steel drain pans with cross breaks and positive slope
  • Efficient permanent split capacitor motors
  • Water, Glycol, Steam, DX or Electric Coil options c/w face and bypass if desired
CSA - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 16 gauge cold rolled steel*
  • 1” - 3” pcf insulation*
  • 14 gauge optional

FINISHES

  • Powder coat textured paint*
  • Special colours

ACCESS

  • Lift out doors (VUV & HUV)*
  • Hinged doors (RUV & SUV)*
  • Camlock fasteners*
  • Seperator piping pockets*

CONTROLS

  • Factory wiring*
  • Damper actuators

CUSTOM

  • Height
  • Width
  • Length
  • Access
  • Materials
  • Piping Pockets

CUSTOM

  • A Coils
  • Plenum fans
  • Energy Recovery
  • Packaged Cooling
  • Raised Condenser
  • UVC & Odor Control

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


  • Riser Style Unit Ventilator

  • HIgh efficiency indirect fired heat exchanger

  • Two stage heating control or modulating (optional)

  • ETL Certified (Canada and USA)

RUVG Series

Institutional and Commercial Gas Fired Unit Ventilators

 

 

Features


  • Heavy duty 16 gauge (1.5mm) steel cabinet.
  • Durable textured powder coat finish
  • 1” (25mm) acoustic insulation
  • Stainless steel drain pan, sloped and insulated, c/w ⅞ (22mm) connection
  • Rigid, insulated 14 gauge (1.9mm) fan board
  • Large access panels with key operated cam locks & finger pull tabs
  • Supply air duct collar discharge
  • Mixing plenum with extrude dampers
  • Quiet operating direct drive DIDW FC fans
  • Multi-speed PSC motors with quick connect
  • 2” (50mm) disposable filter
  • High efficiency heating and cooling coils
  • Wide variety of control options
INTERTEK - C US - Listed CSA - C US - Listed

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The first HERESITE coating application to the exterior surfaces of finned tube coils took place in the early 1950s. Since that time the HERESITE baking phenolic coating has effectively demonstrated its value in protecting heat transfer coils from corrosive attack, thereby appreciably increasing equipment service life.

The excellent chemical and temperature resistance coupled with the good heat transfer properties of the HERESITE coating have made possible the outstanding results being obtained.

Engineered Air, in searching for corrosion resistant coating for finned tube heat transfer products, realized that HERESITE baked phenolic resins were far superior to any other type of coating on the market, both in terms of heat transfer characteristics and resistance to corrosive attach from an extremely wide range of chemicals.

HERESITE

Corrosion Protection

 

 


Description


HERESITE is the registered trademark for pure phenol-formaldehyde thermosetting resinous coatings.

The HERESITE coating applied to finned tube coils is the P-413 Flexible Brown Baking Phenolic Coating. This coating is applied to either aluminum, copper or steel with equal results.

We feel it is important to emphasize that HERESITE baking phenolic coatings are manufactured and sold only by HERESITE PROTECTIVE COATINGS INC. Further, the application of the HERESITE baking phenolic coating to finned tube coils is performed at the HERESITE plant in Manitowoc, Wisconsin, USA, at Engineered Air in Calgary, Alberta, Canada and at other authorized facilities.

Advantages


Practically all typed of finned tube coils used for oil, water, air, gas and process cooling (and heating) as well as a large condensing coils can be HERESITE protected against damaging environments. Currently, the HERESITE coating of air-conditioning and industrial process coils exposed to corrosive fumes and salt atmosphere is in the increase, with many new applications being found.

HERESITE coating offers a more economical solution that special metals for these applications. Typically, aluminum fin coil coated with HERESITE are more economical than copper fin coils. Special metal casing materials are unnecessary since the HERESITE coating is applied to the casing as well as to the finned tubes. Additionally, HERESITE coated aluminum fins will resist attack from most cleaning agents more successfully than copper fin coils.

Application


The present day HERESITE coating of finned tube coils is the result of many years experience during which time application equipment and procedures have been constantly improved. Today, Engineered Air has one of the largest HERESITE facilities in the world. The enables us to HERESITE coat, on a routine basis, coils up to the following size and weight:

Maximum Fin Dimensions
240” long × 78” wide × 18” deep
Maximum Weight Per Coil
4,000 pounds per coil
Fin Spacing, 1 to 3 tube rows
16 per inch maximum
Fin Spacing, 4 to 6 tube rows
14 per inch maximum
Fin Spacing, 7 and 8 tube rows
12 per inch maximum

The HERESITE coating of finned tube coils is accomplished by a multiple coat application of dipping and baking resulting in complete coating coverage of the fins, tubes, headers, casings, etc. Consequently, protection against corrosion is provided for the entire coil. Due to specialized surface preparation techniques plus the good adhesive properties of the HERESITE P-413 coating, it is possible to efficiently HERESITE coat all the usual metals used in fabricating finned tube coils.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Heating cold outside air with steam or a hot fluid is a risky business at the best of times; there is always a potential for a freezeup! But with steam of hot water, there is nothing better than Engineered Air's LAMIFLO Integral Face and Bypass Heating Coils. In the more Northern climates, with a significant number of hours per year under 32°F (0°C) outdoor air temperature, Engineered Air does recommend the use of glycol solution instead of hot water, particularly in areas where power failures are prevalent.

Full flow is sent through the coil at all times, preventing freezeup. Temperature control is maintained by a series of Face and Bypass Dampers, spaced evenly over the face of the LAMIFLO. Face dampers are employed on both the entering and eliminate unwated heat pickup.

The use of LAMIFLO Face and Bypass Dampers for makeup air applications has a very distinct advantage over valve control. A coil is selected for the very worst condition possible - and then often oversized. When the outdoor air temperature is much warmer than the design point, but still below freezing, a control valve is often oscillating between cracked open and fully closed. In one of those fully closed moments, it doesn't take long to chill and then freeze the stationary fluid in the tubes.

With LAMIFLO Face and Bypass Dampers, the steam or fluid flow is constant during the period that the outdoor air temperature is below freezing. Temperature control is achieved by metering the incoming cold air through multiple narrow heating and bypass channels to mix at the control temperature. The bypass channels have been sized to provide a pressure drop when fully open that is equal to the pressure drop through the coil, or heating channel when fully open, to assure a constant volume of air. The air streams emerging from the narrow channels are LAMINATED and mixing is virtually complete within 36” (0.9m) of the LAMIFLO section.

The advantage of LAMIFLO over conventional internal or external face and bypass dampers is clean; the homogenous air temperature mix is far superior, and downstream devices, for example, reheat coils, cooling coils, or humidifiers, need not be spaced a great distance from the LAMIFLO section to retain even velocity loading. Air pressure drop is minimal on LAMIFLO coils. Conventional bypass dampers, with all the bypass air passing over top of the heating coil, create a system effect that demands extra horsepower.

LAMIFLO Series

 

 

Features


  • Uniform heat for makeup air applications
  • Steam, hot water or glycol
  • Minimizes temperature swing
  • Eliminates stratification
  • Vertical and horizontal configurations
  • Installation in ductwork or Engineered Air units


Why LAMIFLO Face & Bypass Heating Coils?

Features Benefits
Integral heating coil and bypass sections Provides safe, even heat for make up air applications
Two sets of face dampers (upstream & downstream) Eliminates coil “wiping”. Mixing is virtually complete within 36” (914mm)
Balanced pressure drops in coil and bypass sections Provides constant air flow at each extreme of operation
Coil sections designed for full flow of steam, water or glycol Maximizes freeze protection
Horizontal or Vertical configuration Accommodates steam, hot water or glycol as well as piping considerations
Heavy duty construction Suitable for commercial and industrial applications
Factory assembled and pressure tested. Dampers are set and welded Assures trouble free operation
Optional CSA B51 pressure vessel code certification and construction for resale coils Accommodates high pressure steam, hot water and glycol applications with copper or steel tubes
Optional in house HERESITE coated coils Provides effective resistance to corrosion of fins, tubes and headers
ARI certified ratings of ⅝” water coils Assures performance based on certified catalog data

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


AIRTEX LINEAR PANELS

The Airtex extruded aluminum panels in lengths up to 16' (4877mm) have changed the way North America heats its buildings. Clean durable Airtex Radiant Linear products are great for the hospital, school, laboratory and office.

A continuous architectural perimeter band constructed to virtually any panel width from interlocking extrusions.

An innovative mechanical bonding technique maximizes heat transfer between copper circulating coils and aluminum extrusions.


AIRTEX MODULAR PANELS

Airtex Modular Radiant Panels fit in standard acoustic ceiling tile grids and can be placed almost anywhere a regular ceiling tile might go.

An efficient, patented metallurgical bonding technique between copper coil and aluminum sheet.

Panel face can be custom coloured or silk-screened to match acoustic ceiling tile.

AIRTEX Radiant Panels

Radiant Ceiling Systems - The New Standard in Perimeter Heating

 

 



Major Applications


  • Educational Facilities

    Durable and efficient AIRTEX Panels provide the necessary wall space, occupant comfort and freedom of maintenance desired in al schools.

  • Hospitals

    AIRTEX Systems provide ultimate patient comfort in an aseptic environment, with no maintenance.

  • Office Buildings

    AIRTEX Systems meet architectural criteria for aesthetics, energy and space efficiency plus easy tenant flexibility.

  • Airports

    AIRTEX Systems provide a clean, draftless, uniform environment with unlimited use of perimeter space.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The AF Series Condenser is constructed of heavy gauge galvanized metal selected for long life in outdoor environments.

The Condenser coil is of copper tube / aluminum fin construction as standard although other materials are available as an option. Custom circuiting is utilized to provide optimum capacity with minimum pressure drop.

Proven components, which have withstood the rigorous test of time, are used in the air moving assemblies. Venturi openings are spun to exacting tolerance to insure maximum airflow with minimum horsepower requirements.

All electrical components (standard or optional) are of the highest quality.

AF Series

Air Cooled Condensers

 

 

CSA - C US - Listed

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The C-TRAC Cooling Sequencer is a fully integrated Heating-Cooling control with Economizer, intended for use with packaged Direct Expansion cooling units, packaged air handlers with remote condensing units, or air handlers with chilled water and hot water coils.

It is the highest level of the TRAC Family. Other Engineered Air TRAC controllers can be slaved to the C-TRAC. The slaved heating controller receives a 0-10VDC control signal from the C-TRAC.

C-TRAC

Cooling Sequencer

 

 



The TRAC family of product specific controls have been designed:

  1. To provide precise control, white also incorporating operating and safety limits
  2. To eliminate electro-mechanical devices, (switches, relays, etc) by means of logic based programming.
  3. To provide rugged, dependable controllers than can withstand the rigors of a rooftop installation. The ability to operate at -40°F ambient and in the presence of electronic noise are essential


Technical Data

Power Supply: 24 VAC - 10VA

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

Inrush Rating: 1800VA

Digital Inputs (DI): 3Digital Outputs (DO): 5
  • Ambient Changeover
  • Economizer Changeover
  • Night Set-back
  • 5 Cooling Stages
Analog Inputs (AI): 4Analog Outputs (AO): 2
  • Discharge Air Temperature Sensor
  • Discharge Air Temperature Setpoint
  • Reset Air Temperature Sensor ambient or room
  • Return or room Air Temperature Setpoint
  • Economizer: 0-10VDC or 4-20ma or 135 Ohm
  • Heating Output: to 0-10VDC Operator OR interfaced to TRAC Controller
Ambient Operating Temperature LimitsTemperature Sensors

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

1000 ohm Thin Platinum Positive Temperature Coefficient Devices (PTC)

Economizer Minimum PositionDead Band

0 - 100%

Fully adjustable 5°F to 12°F

Timing FunctionsControl Algorithms
  • Minimum Compressor Run Time: 4 min.
  • Minimum Compressor Off Time: 4 min.
  • Minimum Interstage Time: 4 min.
  • Room Control
  • Discharged Air Control
  • Discharged Air Control with Room Reset
  • Discharged Air Control with Ambient Reset
  • Discharged Air Control with BMS Reset *
    * analog signal only from BMS

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The G-TRAC Industrial Furnace controller has been designed to provide accurate proportional-integral control for indirect-fired burners with particular emphasis on allowing the burner to turn down to its full capability while maintaining acceptable flue-gas properties. The G-TRAC is unique among industrial gas-fired air heater controllers, in that the air-gas ratio is monitored throughout the entire turndown range, which, in the Engineered Air DG Industrial Heater, spans from full fire to 5% of full fire, or a turndown of 20:1.

Together the DG high turndown burner and the G-TRAC controller provide optimum air heater performance.

The G-TRAC is a stand-alone controller for the Engineered Air series DG Industrial Furnance. Alternatively it can be slaved from the C-TRAC Cooling Sequencer for integrated control of a packaged air conditioner, such as the Engineered Air FW-DG, or a split system using a DG heat section and a CU condensing unit.

G-TRAC

Industrial Gas Heater Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

Inrush Rating: 1800VA

Digital Inputs (DI): 4Digital Outputs (DO): 8
  • Fan Proving Switch
  • Heat Enable Switch
  • Night Operation
  • Feedback for Flame On Status
  • Supply Blower
  • Combustion Blower
  • Flame Relay
  • Inlet Air Damper Motor
  • Inlet Air Damper Motor
  • Alarm
  • Pilot Valve Operator (floating point control)
  • Gas Valve Operator (floating point control)
  • Combustion Air Operator (floating point control)
Analog Inputs (AI): 6Status Indication:
  • Discharge Air Sensor
  • Discharge Air Setpoint
  • Remote Reset Sensor
  • BMS Reset
  • Gas Valve Position Feedback
4 LED's on face of panel provide status information including the following:
  • Heat Call
  • Prepurge Timer
  • Burner On
  • Lockout Alarm: Flame Failure of Low Limit
Ambient Operating Temperature LimitsTemperature Sensors

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

1000 ohm Thin Film Platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The Engineered Air DJ Series indirect fired burners offer superior turndown and modulates both gas firing rate and combustion air quantity.

The DJM controller is a programmed logic device that provides proportional-integral control when used with any one of the DJ series burners. The basic function of the DJM is to control discharge air temperature. The discharge air setpoint can be set either at a fixed value, or can be reset from a number of options.

The DJM in its various forms can operate as either a stand-alone controller, or it can be interfaced with our C-TRAC mechanical cooling controller.

DJM Series

Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

Current Draw: 1.2 amps

Digital Inputs (DI): 4Digital Outputs (DO): 5
  • Fan switch
  • Night setback
  • Heat switch
  • Proof of flame from ignition control
  • Damper motor
  • Ignition control
  • Supply air blower
  • Pilot valve
  • Alarm
Analog Inputs (AI): 6Analog Outputs (AO): 2
  • Combustion blower speed sensor
  • Discharge air temperature
  • Discharge setpoint
  • Room (or ambient) temperature
  • Room (or ambient) setpoint
  • 0-10 vdc or 4-20 ma reset signal
  • Modulating valve output
  • Combustion air blower output
Status IndicationAmbient Operating Temperature Limits

4 LED's on face of panel.
Based on a flashing rate these lights indicate:

  • Discharge Temperature/low limit status
  • Prepurge status
  • Supply blower status
  • Flame status

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

Temperature Sensors
1000 ohm thin film platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The H-TRAC controller has been designed to control staged electric heat applications. It utilizes a proportional-integral control stategy to sequence five binary style output stages.

The electric heat coil controlled by an H-TRAC controller is specifically designed with stages sized for operation with the binary control logic. Stage one is smallest, stage two is double stage one, and stages three, four and five are each four times the output of stage one. In this manner by activating various combinations of the physical stages, fifteen "equivalent" control stages are created (7 or 11 equivalent stages can also be provided.)

The H-TRAC can be used in a variety of control applications. Avaliable options are:

  • Discharge air control with 135 Ω proportional controller

  • Discharge air control with Maxitrol electronic sensor and setpoint adjustment

  • Room control with modulating high and low limits

  • 0-10VDC or 4-20MA reset of discharge air setpoint

  • Direct control from a higher level controller (i.e. H-TRAC becomes a slaved controller)

H-TRAC

Heat Sequencer

 

 



Technical Data

Power Supply: 24 VAC

Current Draw: 6VA

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

Inrush Rating: 1800VA

Digital Inputs (DI): 0Digital Outputs (DO): 5
None.
  • 1st stage heat output 1/15th of total
  • 2nd stage heat output 2/15th of total
  • 3rd stage heat output 4/15th of total
  • 4th stage heat output 4/15th of total
  • 5th stage heat output 4/15th of total
Analog Inputs (AI): 4Analog Outputs (AO): 0
  • 135 ohm three wire proportional
  • 0-10 vdc or 4-20 ma direct control
  • discharge air temp
  • discharge temperature setpoint
None.
Status IndicationAmbient Operating Temperature Limits

One LED behind panel.
Off indicates temperature satisfied.
On indicates a stage is about to switch on or off.

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The rate of heat transfer in a QDT heat pipe is dependent not only on the size, number of rows and fins, but also on the mounting angle. The Q-TRAC controller is designed to operate the tilt mechanism on a QDT heat pipe to control tilt angle.

Controlling the rate of heat transfer via tilt angle of the heat pipe has three objectives.

  • Temperature control: supply air temperature leaving the heat pipe.

  • Frost Prevention: maximizing heat transfer while preventing the formation of frost on the exhaust leaving side of the coil.

  • Heating-Cooling changeover: by reversing the tilt angle, the direction of heat transfer is also reversed to allow summer operation.


The Q-TRAC control is a stand alone solid state device that provides proportional-integral control for all three functions when mounted on a QDT heat pipe with tilt mechanism.

Q-TRAC

QDT Heat Pipe Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

Digital Inputs (DI): 2Digital Outputs (DO): 2
  • Discharge Air Override
  • Frost Mode Air Switch
  • Auxiliary Heat
  • Auxiliary Defrost
Analog Inputs (AI): 2Analog Outputs (AO): 2
  • Supply Discharge Air Sensor
  • Exhaust Leaving
  • Tilt Mechanism Operator
  • Auxiliary Modulating Heat
Status IndicationAmbient Operating Temperature Limits

3 LED's on face of panel.

  • Maximum Heat Reclaim
  • Outside Deadband
  • Exhaust Cold

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

Temperature Sensors
1000 ohm thin film platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The rate of heat transfer in an Engineered Air heat wheel is dependent on the rotation speed of the heat wheel.

The W-TRAC controller is designed to provide variable speed control for an Engineered Air heat wheel. By controlling the rotational speed of the head wheel, and in turn controlling the rate of heat transfer, three functions can be accomplished.

  • Control of supply air temperature leaving the head wheel.

  • Prevention of frost formation on the exhaust side of the wheel while keeping heat transfer at the maximum allowable level.

  • Heating-Cooling changeover. In heating mode heat is carried from the warm exhaust to the cold outside air. In cooling mode heat transfers from the warm outside air to the cooler exhaust air. The wheel simply rotates in either case and as such there is no difference in operation between heating and cooling. By stopping the wheel completely a free cooling mode can be provided. This is desirable if cooling is required and outside air is colder than the exhaust air.


The W-TRAC controller is a stand alone solid state device that provides proportional / integral control for all three of the above functions when mounted with an Engineered Air wheel.

When combined with a DC drive motor the W-TRAC can provide exceptional high turndown speed control. DC drive motors offer the advantage of high torque ability at very low speeds. The W-TRAC can also provide a 0-10 vdc control signal to a variable frequency drive if conditions require the use of an AC drive motor.

W-TRAC

Heat Wheel Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 48VA @ 4VAC, 240VA @ 120VAC

Digital Inputs (DI): 0Digital Outputs (DO): 2
None.
  • DC motor start/stop
  • VFD start/stop
Analog Inputs (AI): 5Analog Outputs (AO): 2
  • Supply discharge air temperature
  • Exhaust leaving air temperature
  • Ambient air temperature
  • Exhaust air relative humidity
  • Return air relative humidity
  • DC Motor speed control
  • 0-10 vdc for VFD motor control
Status IndicationAmbient Operating Temperature Limits

5 LED's on face of panel.

  • Low exhaust temperature
  • Faulty sensor
  • Vent mode
  • Frost mode
  • Discharge temp too high

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

Temperature Sensors
1000 ohm thin film platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The Engineered Air M-TRAC controller is designed to control Engineered Air HE Series direct fired burner on make up air units. M-TRAC controller is a programmed logic device that provides a stable PI (proportional + integral) temperature control and airflow monitoring system. A dual sensor option is built in the M-TRAC controller to provide an even discharge temperature.

The M-TRAC controller has eliminated many mechanical parts such as air proving switch, damper end switch, timers and relays. The M-TRAC provides interlock between the exhaust fan and the make up air unit. This allows the M-TRAC to prove the operation of both the exhaust fan and supply fan. Reverse interlock is also available. This feature is designed for use in buildings which should not go into a negative pressure condition during start up mode.

The Engineered Air M-TRAC controller is designed to be user friendly. The controller is equipped with five diagnostic LED lights. System status can be determined by the LED color and its flashing patterns. This features allows easier troubleshooting.

The M-TRAC in its various forms can operate as either a stand-alone controller, or it can be interfaced to a higher level controller such as a C-TRAC or programmable controller. When used as a stand-alone device the controller provides most of the control requirements of a make up air unit. Standard abilities include: discharge temperature control, supply blower control, burner management, inlet damper control, auto bypass low limit, and air flow monitoring.

M-TRAC

1.3 Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 72VA @ 24VAC, 360VA @ 120VAC

Current Draw: 1.2 amps

Digital Inputs (DI): 5Digital Outputs (DO): 5
  • Fan switch
  • Main gas valve feedback
  • Heat switch
  • High limit switch
  • Proof of flame from ignition control
  • Damper motor
  • Ignition control
  • Supply air blower
  • Pilot Valve
  • Alarm
Analog Inputs (AI): 5Analog Outputs (AO): 1
  • Discharge air temperature
  • Discharge setpoint
  • Profile plate pressure
  • Room setpoint
  • 0-10 vdc or 4-20 ma reset signal
  • Modulating valve output
Status IndicationAmbient Operating Temperature Limits

5 LED's on face of panel. Based on flashing rate these lights indicate:

  • Discharge temperature/low limit status
  • Burner status
  • Air flow status
  • Flame Status
  • Operation Status

Maximum: 120°F ( 49°C )

Minimum: -40°F ( -40°C )

Temperature Sensors
1000 ohm thin film platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The S-TRAC controller has been designed to control Engineered Air SH Series of gas fired humidifiers. It utilizes a proportional-integral control strategy to modulate humidity level.

The Engineered Air S-TRAC controller is a programmed logic controller. It has eliminated many mechanical parts such as timers, relays and water level controller. The S-TRAC provides water level, burner, humidity and system status control. It also has a built in drain cycle timer. The S-TRAC controlled SH humidifier will initiate a drain cycle depending on the hardness of the water and the firing rates of the burner. A mixing valve is also incorporated in the S-TRAC to eliminate high drain temperature.

The S-TRAC can be used in a variety of control applications.

  • Room humidity control c/w S-TRAC built-in setpoint

  • Room humidity control c/w BMS 0-10VDC setpoint

  • Return air humidity control c/w S-TRAC built in setpoint

  • Return air humidity control c/w BMS 01-10VDC setpoint

  • BMS 4-8VDC direct control

  • Ambient reset (to prevent unwanted condensation forming on windows and walls)

  • Duct high humidity limit

S-TRAC

Humidifier Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

Current Draw: 6VA

Inrush Current: 1800 VA

Digital Inputs (DI): 3Digital Outputs (DO): 4
  • Humidity high limit
  • Low water level control
  • High water level control
  • Flame relay
  • Fill valve
  • Mix valve
  • Drain valve
Analog Inputs (AI): 5Analog Outputs (AO): 1
  • BMS 0-10vdc setpoint
  • BMS 4-8vdc direct control
  • Room/Return air humidity control
  • Drain sensor
  • Ambient sensor
  • Modulating gas valve
Status IndicationAmbient Operating Temperature Limits

2 LED's on face of panel. Based on flashing rate these lights indicate:

  • Tank water level status
  • Burner status
  • Operation status

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

Temperature Sensors
1000 ohm thin film platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air X-TRAC is a logic controller designed to control XE, RT, PACK and DJ(E)-20&40 with constant combustion air. The X-TRAC was designed to replace the Maxitrol controller, provide excellent temperature control, increase control flexibility, and provide safety features as provided by other TRAC controllers used for gas heat.

The X-TRAC through the use of digital electronics, has eliminated many of the traditional control components resulting in fewer parts, simplified wiring diagrams and reduced wiring. The X-TRAC replaces the Maxitrol Series 21 amplifier & auto bypass low limit.

The X-TRAC uses a control scheme incorporating Proportional and Integral control (PI) to maintain discharge temperature at set point.

The X-TRAC was designed to be easily applied to the following control applications:

      Discharge control with internal or remote setpoint

      Two level room control. When room thermostat closes, discharge temperature is reset upward to a second discharge set point

      Discharge control c/w external 4-20MA or 0-10VDC reset from BMS. Reset amount ranges from 5°F to 50°F


X-TRAC has built in non-recycling auto bypass low limit. It also has a self-check feature that ensures that the discharge sensor is operating within its tolerances. Two built-in status lights for heat call & lock out are provided.

X-TRAC

Controller

 

 



Technical Data

Power Supply: 24 VAC

Contact Rating: 70VA @ 24VAC, 360VA @ 120VAC

0.8 amps

Digital Inputs (DI): 4Digital Outputs (DO): 2
  • Fan switch
  • Heat switch
  • Heating override
  • Proof of flame from ignition control
  • Ignition control
  • Supply air blower
Analog Inputs (AI): 4Analog Outputs (AO): 1
  • Discharge air temperature
  • Discharge setpoint
  • Room setpoint
  • 0-10 vdc or 4-20 ma reset signal
  • Modulating valve output
Status IndicationAmbient Operating Temperature Limits

2 LED's on face of panel. Based on flashing rate these lights indicate:

  • Discharge temperature/low limit status
  • Flame status

Maximum: 105°F ( 40°C )

Minimum: -40°F ( -40°C )

Temperature Sensors
1000 ohm thin film platinum Positive Temperature Coefficient Device (PTC)

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The Engineered Air DJX Series furnaces redefine heating for the commercial – industrial market place. Our complete line of indirect gas-fired heating products incorporates independent proportional control of combustion air and gas flow. This ability to maintain the proper ratio of combustion air to gas burned is called “linearization”.

With Linearization our DJX Series product maximizes heating efficiency and Energy Savings. DJ models meet or exceed the ASHRAE 90.1 2007 and ASHRAE 189.1 high performance building requirements for (non weatherized) steady state at high fire operation.

The DJX heat exchanger was engineered to operate at nominal 91% efficiency throughout its complete firing rate and with increased efficiency during part load conditions. The DJX Series exceeds standards and optimizes energy performance.

DJX Series

Indirect Condensing Appliance

 

 

Features


  • Air Flow Rate from 1,000 to 44,000 CFM
  • Gas Fired Heating 100 MBH to 1,400 MBH
  • Turndown Ratio up to 15:1
  • Indoor and Outdoor Configurations
INTERTEK - C US - Listed

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Standard Features


  • Slide out burner / control assembly, and blower / motor assembly, for ease of servicing
  • Washable hammock style filters
  • Blowers with ball bearings
  • Aluminized steel heat exchangers
  • USA - Derate Natural Gas sea level inputs 4% for every 1000 ft. above sea level
  • Canada - Derate Natural Gas sea level inputs by 10% to achieve high altitude ratings
CSA - C US - Listed

OPTIONS


  • Stainless steel heat exchangers
  • Electronic ignition
  • Power vented (standard on XE-320)
  • Mixing box and controls
  • Electro (Maxitrol) modulating make-up air discharge control, with provisions for space temperature override
  • Auto low limit controls
  • Remote Panels
  • Additional options for custom series: one inch insulation, pillow block bearings and internal rubber-in shear isolation, D.X. cooling coil, two inch pleated panel filters

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


RT Series

Outdoor Heating Units

 

 

Standard Features


  • Weatherproofed Casing - designed to withstand Canadian weather conditions
  • Convenient Remove Start - electronic flame safeguard; reset accomplished at thermostat
  • Aluminized Heat Exchangers
  • Direct Spark Ignition - 19,000 volt synchronous direct spark ignition system eliminates pilot
  • Powered Venting - constant draft regardless of outside weather conditions
  • USA - Derate Natural Gas sea level inputs 4% for every 1000 ft. above sea level
  • Canada - Derate Natural Gas sea level inputs by 10% to achieve high altitude ratings
CSA - C US - Listed

Options


  • Stainless steel heat exchangers
  • Matching roof curb package
  • Remote panels
  • Mixing box and controls
  • Fresh air hood w or w/o 2 position damper package
  • Mechanical modulating make-up air discharge air control
  • Electronic (Maxitrol) modulating make-up air discharge air control, with provisions for space temperature override
  • Auto low limit controls
  • Pressure switch to indicate clogged filter
  • Time clock for occupied / unoccupied remote fan switching at thermostat
  • Additional options for custom series: one inch insulation, pillow block bearings and internal rubber-in shear isolation, D.X. cooling coil & cabinet, two inch pleated panel filters

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


The Engineered Air MC Series is a line of modular water-cooled and remote air-cooled chillers (packaged air cooled are available) that range in size from 20 to 80 nominal tons. They can operate as a stand alone unit or in combination of up to 12 chiller modules to increase cooling capacity as needed. Single stand-alone models are available in the 3 to 80 ton range.

The principle of modular chiller design is that a smaller individual chiller (a module) can be connected with other modules to create a larger cooling system, either initially or over time. Sections of 6" (152mm) diameter pipe connected with Victaulic couplings are used to form a common header. This allows the common header to be pre-shipped to the job site and piped into the building piping system before the rest of the equipment arrives.

MC Series Modular Chillers

Commerical & Industrial Water or Air Cooled Modular Chillers

 

 

Features / Options


  • Single stand alone chillers or up to 12 units in a modular configuration
  • Energy efficiency verified models
  • Service any module while the rest of the system continues to cool
  • Display showing descriptive system information on each module
  • Controller automatically removes serviced unit
  • Victaulic water-header connections
  • Easy acces to major components
  • Fits through 28
  • Simple system expansion
  • Match capacity at any load with multiple units
  • Master controller for control of modular configurations
  • Packaged or remote air cooled condensers
INTERTEK - C US - Listed CSA - C US - Listed

Typical Options ( * ) represents standards features

CASING

  • 2” (51mm) square tubing*
  • Black tubing / gray enamel*
  • Accoustical housing
  • Special corrosion protection
  • Epoxy paint

COOLING

  • R-410A refrigerant*
  • R-134a refrigerant
  • Low ambient kit
  • Remote air-cooled condenser
  • Head pressure control kit
  • Hot gas bypass valves

CONTROLS

  • Dedicated logic controller*
  • Dead front disconnect *
  • Hours of operation*
  • Phase loss detection
  • BACnet
  • Various control strategies

WATER SIDE

  • 6” (152mm) headers with isolation valves*
  • Automatic isolation valves
  • Y - strainers
  • Water regulating valves

Typical Options (*) represents standard features


Casing / FinishesCoolingWater SideControls
  • 2" (51mm) square tubing*
  • Black tubing / gray enamel*
  • Accoustical housing
  • Special corrosion protection
  • Epoxy paint
  • R-410A refrigerant*
  • R-134a refrigerant
  • Low ambient kit
  • Remote air-cooled condenser
  • Head pressure control kit
  • Hot gas bypass valves
  • 6" (152mm) headers with isolation valves*
  • Automatic isolation valves
  • Y - strainers
  • Water regulating valves
  • Dedicated logic controller*
  • Dead front disconnect *
  • Hours of operation*
  • Phase loss detection
  • BACnet
  • Various control strategies

Benefits


Expandability
Allows the system to grow with the cooling load. Modules can be added at a future date without doing any piping work.

Better Capacity Control Each individual circuit is operating at its optimum efficiency point, providing a high operating efficiency even though the overall assembly is operating at partial load.

Installation
Units are connected to the header using isolation valves and flex joints, meaning they can be mounted directly onto a concrete slab. Header sections are identical to one another. They can be pre-shipped ahead of the chillers, allowing the building piping system to be pre-built.

Flexible Installation Arrangements
The external common header means that modules can be located in different parts of the room or even in separate rooms. As long as the piping is connected so that the master controller measures the system fluid temperature, the system will work effectively.

Service While Under Full Operation
Designed to allow service to all the liquid line components on any of the chillers while the system is under operation.

Redundancy
Add one more module to the system for an "N + 1" capacity so that the overall cooling system capacity is not affected when a module is taken out for regular service or needs repair. Each unit has two independent circuits. If one is lost, only that circuit is affected while all others remain operational. Each module has a fully functioning dedicated logic controller. If communication is lost with the master controller, the individual controllers will automatically take over control of each module. By presetting and staging the set points on all the local controllers, they will then control the system.

Front Serviceability
Set up so that it is front serviceable making it easy to access components requiring routine maintenance.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Direct Drive Fan Coil Units (Blow Through) are available in three different models:

  • HFC - Horizontal
  • VFC - Vertical
  • LFC - Lowboy


Belt Drive Fan Coil Units (Draw and Blow Through) are available in three different models:

  • JM - Horizontal
  • JMV - Vertical
  • MT - Horizontal

Options


  • Custom sizes, arrangements and performance ratings
  • Recessing flanges and leveling bolts
  • Special materials for casings, drain pans, coils and fans
  • High static pressure models
  • Extra heavy 16 GA (1.5mm) construction (standard on exposed units)
  • High density, acoustical insulation, 3 lb/ft^3 (48 kg/m^3) with neoprene coating
  • Throw away, permanent washable or replaceable media filters
  • Special motors: totally enclosed, special voltages
  • Auxiliary hot water, steam or electric heating coils
  • Extra high capacity cooling coils
  • Unit or remote mounted, variable or 3 speed controllers, thermostats and starters
  • Valve control packages
  • Ultra quiet design

Direct Drive Fan Coil Units
Models: HFC, VFC and LFC


Cabinets Concealed units shall be fabricated with heavy 18 gauge (1.2mm) satin coat galvanized steel. Exposed units shall be 16 gauge (1.5mm) galvanneal steel and be treated to a multi-step preparation process before the application of an electrostatically applied, baked white powder coat primer. Cabinets shall be lined with 1" (25mm) neoprene coated insulation. Condensate pans shall be stainless steel and be insulated with closed cell insulation for sweat proof operation and corrosion resistance. All units shall come complete with a 1" synthetic disposable filter, as well as being equipped with an electrical junction box.
Coils Heating and cooling coils shall be manufactured by Engineered Air and consist of aluminum fins mechanically bonded to 1/2" (13mm) copper tubes. Fins shall be rippled for maximum heat transfer and coil casings shall be galvanized steel. Coils shall be factory tested with air at 300 psig (2070 kPa) while immersed in an illuminated water tank.
Fans Double width, double inlet, forward curved centrifugal fans constructed of galvanized steel shall be provided. Fans shall be balanced for quiet, vibration free operation and be supplied with housing specifically designed for efficient airflow.
Motors All motors shall be open type, resiliently mounted, incorporating sleeve bearings and internal overload protection. Motors shall be permanent split capacitor type. All motors shall be equipped for 115/1/60 and be capable of at least three speeds.
Approval

All units shall be safety tested to conform to UL Standard 1995 and CSA.2 No. 236. Units shall be CSA approved and bear the CSA label.

Units shall be Engineered Air series HFC (horizontal blow thru), VFC (vertical blow thru), or LFC (lowboy blow thru) with model, sizes, capacities, motor types, H.P. (kW) and power characteristics as indicated on drawings and/or schedules.

Belt Drive Fan Coil Units
Models: JM, JMV and MT


Cabinets Casing shall be constructed of 18 gauge (1.3mm) unpainted satin coat galvanized steel. Units shall include 1" (25mm) 1 1/2" lb/ft^3 (24 kg/m^3) insulation, integral stainless steel drain pan, slotted hanger channels, duct collars on inlet and outlet, screwed access panels, adjustable motor mounts and 2" (50mm) throwaway filters. Unit construction is one piece. Units are factory tested. Field assembly of components, including mounting of motor and drives is not acceptable..
Coils Heating and/or cooling coils shall be 1/2" (13mm) copper tube with rippled aluminum fins and Schraeder vent fittings on fluid coils. D.X. coils shall include distributors. Expansion valves and refrigeration accessories are by refrigeration contractor (others).
Approval

All units shall be safety tested to conform to UL Standard 1995 and CSA.2 No. 236. Units shall be CSA approved and bear the CSA label.

Units shall be Engineered Air model JM (draw through), JMV (vertical draw through), or MT (blow through) with model number, sizes, capacities, motor types, H.P. (kW), and power characteristics as indicated ond rawing and/or schedules.

View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's Flush Grid System provides a variety of options from our standard welded bottom load, top load and stainless steel grids to our economical stick-built ceiling grid systems. Our vast array of Flush Ceiling Grids can be supplied with integral lighting and sprinklers to provide flexibility for your cleanroom needs.

 

 


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Engineered Air's Cleanroom Plenum System provides custom modules manufactured to facilitate ease of installation and the ability to fit into a confined ceiling space. These modules can be supplied with plenum fans, coils, integral LED lighting and sprinklers, as well as a variety of controls.

 

 


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.


Operating Suites in today's market demand a lot of interface with the ceiling system. Engineered Air offers the perfect solution to customize the plenums with structural steel that allow the medical equipment to hang from, including boom mounts and rails. Our Flush Ceiling Grid allows for integration of LED lighting above the patient while allowing filtered air to be balanced precisely, at the desired velocity, to wash over the operating table.

 

 


View Brochure PDF Request Access to our Complete Catalog

Due to continuous product development, specifications, dimensions and capacities are subject to change without notice.